B-Series Gear Pump

Trouble Probable Cause and Remedy
  • Pump will not turn
  • Drive malfunction:  verify that drive powered.  Assure all alarm circuits are clear.  Check drive motor current and speed settings.

  • Process conditions changed:  check process conditions for proper temperature, pressures, viscosities, and materials.

  • Entrained particle:  disassemble and clean pump.  Replace any damaged parts.

  • Possible internal damage:  disassemble and clean pump.  Replace any damaged parts.  Consult factory.

  • No flow from pump
  • Same as above:  same as above.
  • Pump rotation:  correct drive arrangement or power leads.
  • Excessive seal assembly leakage
  • Worn lip seal:  replace lip seals.
  • Worn seal plate:  replace seal plate and coupling if necessary.
  • Insufficient inlet pressure:  mechanical face seal version - increase inlet pressure.
  • Reduced pump efficiency
  • Worn gear(s):  replace worn gear(s).
  • Worn bearings:  replace worn bearings.
  • Process conditions changed:  consult factory for gear clearance recommendations for new process conditions.